A New Approach to Retinal Oxygen Extraction Measurement Based on Laser Speckle Flowgraphy and Retinal Oximetry

Viktoria Pai, Patrick Janku, Theresa Lindner, Ulrich Graf, Leopold Schmetterer, Gerhard Garhöfer, Doreen Schmidl

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Currently, no standard for the measurement of retinal oxygen extraction exists. Here, we present a novel approach for measurement of retinal oxygen extraction based on two commercially available devices, namely laser speckle flowgraphy (LSFG) and retinal oximetry. Methods: The study was conducted in a randomized, double-masked design. Two study days were scheduled for each healthy participant. On one study day, measurements were performed during breathing of 100% oxygen to induce hyperoxia and on the other study day during breathing of 12% oxygen in nitrogen to induce hypoxia. To obtain data for short- and long-term reproducibility, baseline measurements during breathing of room air were performed twice on both study days. Retinal oxygen extraction was calculated from retinal oxygen saturation measurements using the oxygen module of the dynamic vessel analyzer (Imedos, Jena, Germany) and retinal blood flow measurements using LSFG (Nidek, Tokyo, Japan). Results: As expected, breathing of 100% oxygen induced a significant decrease in retinal oxygen extraction of 36% ± 17% (P < 0.001). During hypoxia, retinal oxygen extraction did not change from baseline (P = 0.153). For short-term reproducibility, the intraclass correlation coefficient was excellent (0.910) and good (0.879) for long-term reproducibility. Coefficient of variation between measurements was 9.8% ± 7.0% for short-term and 10.4% ± 8.8% for long-term reproducibility. Conclusions: The data obtained in the present experiments show that the new approach to measure retinal oxygen extraction is valid and reproducible in healthy volunteers. Translational Relevance: The technique may become a valuable tool in studying retinal hypoxia in a wide variety of ocular and systemic diseases in the future.

Original languageEnglish
Pages (from-to)12
Number of pages1
JournalTranslational Vision Science and Technology
Volume13
Issue number12
DOIs
Publication statusPublished - Dec 2 2024
Externally publishedYes

ASJC Scopus Subject Areas

  • Biomedical Engineering
  • Ophthalmology

Fingerprint

Dive into the research topics of 'A New Approach to Retinal Oxygen Extraction Measurement Based on Laser Speckle Flowgraphy and Retinal Oximetry'. Together they form a unique fingerprint.

Cite this