TY - JOUR
T1 - Changes in retinal blood flow in response to an experimental increase in IOP in healthy participants as assessed with Doppler optical coherence tomography
AU - Puchner, Stefan
AU - Schmidl, Doreen
AU - Ginner, Laurin
AU - Augustin, Marco
AU - Leitgeb, Rainer
AU - Szegedi, Stephan
AU - Stjepanek, Kristina
AU - Hommer, Nikolaus
AU - Kallab, Martin
AU - Werkmeister, René Marcel
AU - Schmetterer, Leopold
AU - Garhofer, Gerhard
N1 - Publisher Copyright:
©Copyright 2020 The Authors
PY - 2020/2
Y1 - 2020/2
N2 - PURPOSE. Blood flow autoregulation is an intrinsic mechanism of the healthy retinal vasculature to keep blood flow constant when ocular perfusion pressure (OPP) is changed. In the present study, we set out to investigate retinal blood flow in response to an experimental decrease in OPP in healthy participants using Doppler optical coherence tomography. METHODS. Fifteen healthy participants aged between 22 and 31 years (mean, 27 ± 3 years) were included in the present open study. IOP was increased stepwise via the suction cup method to induce a decrease in OPP. Retinal blood flow in arteries and veins was assessed using a custom-built Doppler optical coherence tomography system and pressure–flow relationships were calculated to assess autoregulation. RESULTS. Suction cup application induced a pronounced increase in IOP with a maximum value of 50.5 ± 8.0 mm Hg at the highest level of suction. Pressure–flow relationships revealed that blood flow was autoregulated until the OPP was decreased by approximately 21 mm Hg and started to decrease significantly when the OPP was reduced by 30 mm Hg. Retinal blood flow at the last suction period decreased at a maximum of –57.0 ± 22.3% and 65.2 ± 15.4% in retinal arteries and retinal veins, respectively. These changes in retinal blood flow were less pronounced than the decrease in OPP (–75.2 ± 19.2%), indicating retinal autoregulation. CONCLUSIONS. The results of the present study confirm that retinal blood flow is autoregulated in response to changes in the OPP. Doppler optical coherence tomography has the potential to become a clinical tool for the investigation of retinal blood flow autoregulation in the future, because of its ability to assess the blood velocities and diameter of the retinal vessels parallel and therefore also their blood flow in absolute values. (Clinicaltrials.gov
AB - PURPOSE. Blood flow autoregulation is an intrinsic mechanism of the healthy retinal vasculature to keep blood flow constant when ocular perfusion pressure (OPP) is changed. In the present study, we set out to investigate retinal blood flow in response to an experimental decrease in OPP in healthy participants using Doppler optical coherence tomography. METHODS. Fifteen healthy participants aged between 22 and 31 years (mean, 27 ± 3 years) were included in the present open study. IOP was increased stepwise via the suction cup method to induce a decrease in OPP. Retinal blood flow in arteries and veins was assessed using a custom-built Doppler optical coherence tomography system and pressure–flow relationships were calculated to assess autoregulation. RESULTS. Suction cup application induced a pronounced increase in IOP with a maximum value of 50.5 ± 8.0 mm Hg at the highest level of suction. Pressure–flow relationships revealed that blood flow was autoregulated until the OPP was decreased by approximately 21 mm Hg and started to decrease significantly when the OPP was reduced by 30 mm Hg. Retinal blood flow at the last suction period decreased at a maximum of –57.0 ± 22.3% and 65.2 ± 15.4% in retinal arteries and retinal veins, respectively. These changes in retinal blood flow were less pronounced than the decrease in OPP (–75.2 ± 19.2%), indicating retinal autoregulation. CONCLUSIONS. The results of the present study confirm that retinal blood flow is autoregulated in response to changes in the OPP. Doppler optical coherence tomography has the potential to become a clinical tool for the investigation of retinal blood flow autoregulation in the future, because of its ability to assess the blood velocities and diameter of the retinal vessels parallel and therefore also their blood flow in absolute values. (Clinicaltrials.gov
KW - Autoregulation
KW - Doppler optical coherence tomography
KW - Intraocular pressure
KW - Ocular perfusion pressure
KW - Retinal blood flow
KW - Suction cup
UR - http://www.scopus.com/inward/record.url?scp=85079794843&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85079794843&partnerID=8YFLogxK
U2 - 10.1167/iovs.61.2.33
DO - 10.1167/iovs.61.2.33
M3 - Article
C2 - 32084274
AN - SCOPUS:85079794843
SN - 0146-0404
VL - 61
JO - Investigative Ophthalmology and Visual Science
JF - Investigative Ophthalmology and Visual Science
IS - 2
M1 - 2761942
ER -