TY - JOUR
T1 - Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope
AU - Yao, Xinwen
AU - Ke, Mengyuan
AU - Ho, Yijie
AU - Lin, Emily
AU - Wong, Damon W.K.
AU - Tan, Bingyao
AU - Schmetterer, Leopold
AU - Chua, Jacqueline
N1 - Publisher Copyright:
©
PY - 2021/3/1
Y1 - 2021/3/1
N2 - Background/ims To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). Methods Fifteen healthy subjects, 67% women, mean age (SD) 30.87 (6.19) years, were imaged using OCTA and AOO by a single experienced operator on the same day. Each eye was scanned using two OCTA protocols (3×3 mm 2 and 9×9 mm 2) and two to five AOO scans (1.2×1.2 mm 2). The OCTA and AOO scans were scaled to the same pixel resolution. Two independent graders measured the vessel diameter at the same location on the region-of-interest in the three coregistered scans. Differences in vessel diameter measurements between the scans were assessed. Results The inter-rater agreement was excellent for vessel diameter measurement in both OCTA protocols (ICC=0.92) and AOO (ICC=0.98). The measured vessel diameter was widest from the OCTA 3×3 mm 2 (55.2±16.3 μm), followed by OCTA 9×9 mm 2 (54.7±14.3 μm) and narrowest by the AOO (50.5±15.6 μm; p<0.001). Measurements obtained from both OCTA protocols were significantly wider than the AOO scan (OCTA 3×3 mm 2: mean difference "=4.7 μm, p<0.001; OCTA 9×9 mm 2: "=4.2 μm, p<0.001). For vessels >45 μm, it appeared to be larger in OCTA 3×3 mm 2 scan than the 9×9 mm 2 scan ("=1.9 μm; p=0.005), while vessels <45 μm appeared smaller in OCTA 3×3 mm 2 scan ("=-1.3 μm; p=0.009) Conclusions The diameter of retinal vessels measured from OCTA scans were generally wider than that obtained from AOO scans. Different OCTA scan protocols may affect the vessel diameter measurements. This needs to be considered when OCTA measures such as vessel density are calculated.
AB - Background/ims To compare the retinal vessel diameter measurements obtained from the swept-source optical coherence tomography angiography (OCTA; Plex Elite 9000, Carl Zeiss Meditec, USA) and adaptive optics ophthalmoscope (AOO; RTX1, Imagine Eyes, France). Methods Fifteen healthy subjects, 67% women, mean age (SD) 30.87 (6.19) years, were imaged using OCTA and AOO by a single experienced operator on the same day. Each eye was scanned using two OCTA protocols (3×3 mm 2 and 9×9 mm 2) and two to five AOO scans (1.2×1.2 mm 2). The OCTA and AOO scans were scaled to the same pixel resolution. Two independent graders measured the vessel diameter at the same location on the region-of-interest in the three coregistered scans. Differences in vessel diameter measurements between the scans were assessed. Results The inter-rater agreement was excellent for vessel diameter measurement in both OCTA protocols (ICC=0.92) and AOO (ICC=0.98). The measured vessel diameter was widest from the OCTA 3×3 mm 2 (55.2±16.3 μm), followed by OCTA 9×9 mm 2 (54.7±14.3 μm) and narrowest by the AOO (50.5±15.6 μm; p<0.001). Measurements obtained from both OCTA protocols were significantly wider than the AOO scan (OCTA 3×3 mm 2: mean difference "=4.7 μm, p<0.001; OCTA 9×9 mm 2: "=4.2 μm, p<0.001). For vessels >45 μm, it appeared to be larger in OCTA 3×3 mm 2 scan than the 9×9 mm 2 scan ("=1.9 μm; p=0.005), while vessels <45 μm appeared smaller in OCTA 3×3 mm 2 scan ("=-1.3 μm; p=0.009) Conclusions The diameter of retinal vessels measured from OCTA scans were generally wider than that obtained from AOO scans. Different OCTA scan protocols may affect the vessel diameter measurements. This needs to be considered when OCTA measures such as vessel density are calculated.
KW - angiogenesis
KW - imaging
KW - retina
UR - http://www.scopus.com/inward/record.url?scp=85085765783&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85085765783&partnerID=8YFLogxK
U2 - 10.1136/bjophthalmol-2020-316111
DO - 10.1136/bjophthalmol-2020-316111
M3 - Article
C2 - 32461263
AN - SCOPUS:85085765783
SN - 0007-1161
VL - 105
SP - 426
EP - 431
JO - British Journal of Ophthalmology
JF - British Journal of Ophthalmology
IS - 3
ER -