Condition Monitoring of DC-Link Capacitors Using Goertzel Algorithm for Failure Precursor Parameter and Temperature Estimation

Prasanth Sundararajan*, Mohamed Halick Mohamed Sathik, Firman Sasongko, Chuan Seng Tan, Josep Pou, Frede Blaabjerg, Amit Kumar Gupta

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

75 Citations (Scopus)

Abstract

Aluminum electrolytic capacitors are some of the weakest components in a power converter system. Therefore, condition monitoring of capacitors can prevent unexpected system downtime due to capacitor failures. This article proposes a condition monitoring system for electrolytic capacitors used as dc-link capacitors in front-end rectifier-fed three-phase inverters. The proposed methodology is based on equivalent series resistance (ESR) and capacitance estimation using the Goertzel algorithm. The ESR is used as the degradation indicator, whereas the capacitance value is used as both degradation indicator and temperature-sensitive electrical parameter to estimate core or hotspot temperature. Even though the use of capacitance to estimate hotspot temperature has already been proposed, this article tackles the practical difficulties associated with capacitor core-temperature estimation using the capacitance and demonstrates a successful implementation strategy for applying this method in power converters to estimate core temperature online. It also introduces a self-calibration procedure to mitigate ageing-related errors in temperature estimation. An experimental setup is used to verify the proposed conditioning monitoring system. The experimental results prove the effectiveness and accuracy of the proposed technique.

Original languageEnglish
Article number8892651
Pages (from-to)6386-6396
Number of pages11
JournalIEEE Transactions on Power Electronics
Volume35
Issue number6
DOIs
Publication statusPublished - Jun 2020
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 1986-2012 IEEE.

ASJC Scopus Subject Areas

  • Electrical and Electronic Engineering

Keywords

  • Aluminum electrolytic capacitors (AECs)
  • condition monitoring
  • Goertzel algorithm
  • parameter estimation
  • pulsewidth modulated inverters