TY - JOUR
T1 - Continuous, high-throughput production of artemisinin-loaded supramolecular cochleates using simple off-the-shelf flow focusing device
AU - Shuddhodana,
AU - Wong, Pooi Wen Kathy
AU - Judeh, Zaher
N1 - Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2020/3
Y1 - 2020/3
N2 - Lipid cochleates are gaining increasing interest as drug-carriers. However, their preparation relies on conventional batch processes that are complex, time consuming and lack batch-to-batch reproducibility; presenting a bottleneck for clinical translation. We report an efficient continuous preparation process for artemisinin-loaded cochleates (ART-cochleates) using inexpensive off-the-shelf flow focusing device. By carefully controlling the flow focusing parameters, we showed along with the mechanism that, ART-cochleates of uniform and tuneable size (~180 nm in width and ~1030 nm in length) were obtained with low dispersity (0.18 in width and 0.27 in length), narrow size distribution and high reproducibility compared to the batch process. The device achieved high throughput of 11.5 g/day with ART encapsulation of 64.24 ± 2.5% and loading of 83.37 ± 3.68 mg ART/g of cochleates. Art-cochleates were non-toxic and showed sustained in-vitro release of ART with effective transepithelial permeability across intestinal Caco-2 monolayer (~60% and ~25% transport for pure ART and ART-cochleates, respectively) resulting in better in-vitro bioavailability. The off-the-shelf device is envisioned to be highly promising platform for continuous and high-throughput manufacturing of drug-loaded cochleates in a controlled and reproducible manner. It has potential to enable clinical translation of drug-loaded cochleates with predicable drug release, absorption and bioavailability.
AB - Lipid cochleates are gaining increasing interest as drug-carriers. However, their preparation relies on conventional batch processes that are complex, time consuming and lack batch-to-batch reproducibility; presenting a bottleneck for clinical translation. We report an efficient continuous preparation process for artemisinin-loaded cochleates (ART-cochleates) using inexpensive off-the-shelf flow focusing device. By carefully controlling the flow focusing parameters, we showed along with the mechanism that, ART-cochleates of uniform and tuneable size (~180 nm in width and ~1030 nm in length) were obtained with low dispersity (0.18 in width and 0.27 in length), narrow size distribution and high reproducibility compared to the batch process. The device achieved high throughput of 11.5 g/day with ART encapsulation of 64.24 ± 2.5% and loading of 83.37 ± 3.68 mg ART/g of cochleates. Art-cochleates were non-toxic and showed sustained in-vitro release of ART with effective transepithelial permeability across intestinal Caco-2 monolayer (~60% and ~25% transport for pure ART and ART-cochleates, respectively) resulting in better in-vitro bioavailability. The off-the-shelf device is envisioned to be highly promising platform for continuous and high-throughput manufacturing of drug-loaded cochleates in a controlled and reproducible manner. It has potential to enable clinical translation of drug-loaded cochleates with predicable drug release, absorption and bioavailability.
KW - Artemisinin
KW - Cochleates
KW - Continuous production
KW - Lipids
KW - Liposomes
KW - Microfluidic flow focusing
UR - http://www.scopus.com/inward/record.url?scp=85074717221&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85074717221&partnerID=8YFLogxK
U2 - 10.1016/j.msec.2019.110410
DO - 10.1016/j.msec.2019.110410
M3 - Article
C2 - 31923944
AN - SCOPUS:85074717221
SN - 0928-4931
VL - 108
JO - Materials Science and Engineering C
JF - Materials Science and Engineering C
M1 - 110410