Abstract
Mechanical ventilation is required to aid patients with breathing difficulty to breathe more comfortably. A tracheostomy tube is inserted through an opening in the patient neck into the trachea, below the vocal cords. This opening is either created surgically or using a percutaneous dilatational technique. The inserted tube sits in the trachea, above the carina, and before the airways branch into the left and right main bronchi. In mechanical ventilation, the tube is connected to a ventilator and air is moved in and out of the lungs via positive pressure. In this process, mucus will accumulate at the point of branching into the branchi. Currently, this mucus is manually removed half-hour by inserting a suction tube via the tracheostomy to reach the point of branching. Nurses spend millions of person-hours to perform this task yearly. To save significant person-hours, an automated system is needed. This system also allows the patient to recover at home, rather stay in hospital solely for nurses to remove mucus periodically. In this paper, we present a novel mechatronic device to perform automatic tracheal suctioning in conjunction with a tracheostomy tube. A new suctioning catheter is also developed. It is known that nonlinear friction and backlash between the suctioning catheter and its conduit as well as in the gear system of the actuator cause difficulties to accurately control the position of catheter tip. To enhance the system performances, a novel direct inverse of backlash-like hysteresis model-based feedforward is also developed. The designed device and proposed compensation scheme are experimentally validated. The results demonstrate a significant contribution and potential benefits to the mechanical ventilation works.
Original language | English |
---|---|
Title of host publication | Proceedings of the 2015 7th IEEE International Conference on Cybernetics and Intelligent Systems, CIS 2015 and Robotics, Automation and Mechatronics, RAM 2015 |
Publisher | Institute of Electrical and Electronics Engineers Inc. |
Pages | 228-233 |
Number of pages | 6 |
ISBN (Electronic) | 9781467373364 |
DOIs | |
Publication status | Published - Sept 23 2015 |
Externally published | Yes |
Event | 7th IEEE International Conference on Cybernetics and Intelligent Systems, CIS 2015 and the 7th IEEE International Conference on Robotics, Automation and Mechatronics, RAM 2015 - Siem Reap, Cambodia Duration: Jul 15 2015 → Jul 17 2015 |
Publication series
Name | Proceedings of the 2015 7th IEEE International Conference on Cybernetics and Intelligent Systems, CIS 2015 and Robotics, Automation and Mechatronics, RAM 2015 |
---|
Conference
Conference | 7th IEEE International Conference on Cybernetics and Intelligent Systems, CIS 2015 and the 7th IEEE International Conference on Robotics, Automation and Mechatronics, RAM 2015 |
---|---|
Country/Territory | Cambodia |
City | Siem Reap |
Period | 7/15/15 → 7/17/15 |
Bibliographical note
Publisher Copyright:© 2015 IEEE.
ASJC Scopus Subject Areas
- Artificial Intelligence
- Control and Systems Engineering
Keywords
- backlash compensation
- Mechanical ventilation
- robotic catheter
- tracheal suctioning
- tracheostomy tube