Dielectric degradation mechanism for copper interconnects capped with CoWP

T. L. Tan, C. L. Gan, A. Y. Du, C. K. Cheng, J. P. Gambino

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

Time-dependent dielectric breakdown (TDDB) reliability of CoWP-capped copper/ Si O2 interconnect structures are observed to be better than conventional SiN-capped structures. The activation energy for TDDB (Ea) is higher for CoWP-capped structures (0.66-0.84 eV) as compared to SiN-capped ones (0.47 eV), and is comparable to the Ea for intrinsic breakdown of Si O2. The TDDB degradation mechanism in CoWP-capped structures is postulated to be dominated by the properties of the intrametal dielectric, as opposed to being influenced by the properties of dielectric cap and associated interfaces. The presence of the dielectric cap lowers the Ea and increases leakage by Poole-Frenkel emission.

Original languageEnglish
Article number201916
JournalApplied Physics Letters
Volume92
Issue number20
DOIs
Publication statusPublished - 2008
Externally publishedYes

ASJC Scopus Subject Areas

  • Physics and Astronomy (miscellaneous)

Fingerprint

Dive into the research topics of 'Dielectric degradation mechanism for copper interconnects capped with CoWP'. Together they form a unique fingerprint.