Eliminating the dication-induced intersample chemical-shift variations for NMR-based biofluid metabonomic analysis

Limiao Jiang, Jing Huang, Yulan Wang, Huiru Tang*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

50 Citations (Scopus)

Abstract

NMR-based urinary metabonomic analysis is an essential aspect of systems biology for understanding mammalian physiology and pathophysiology though intersample chemical-shift variations can cause serious problems. Here, we report two optimized and validated methods to eliminate such variations resulting from intersample differences in pH and dication concentration. We found that the Ca2+ concentration was 7.41 ± 3.48, 1.03 ± 0.34 and 0.87 ± 0.52 mM whereas the Mg2+ concentration was 3.02 ± 1.41, 2.65 ± 1.20 and 0.80 ± 0.59 mM in rat, mouse and human urine samples, respectively; urinary Ca-EDTA, Mg-EDTA and free EDTA had spin-lattice relaxation time values (600.13 MHz) of 0.38, 0.41 and 0.55 s, respectively. We also found that the combined treatments with potassium fluoride, phosphate buffer and a small amount of K3EDTA eliminated intersample chemical-shift variations for all metabolites. EDTA treatment followed with phosphate buffer also achieved similar results although resonances from EDTA and its complexes obscured some metabolite signals. We systematically optimized the amount of additives for rat, mouse and human urine samples taking into consideration the pH control, signal-to-noise ratio and intersample uniformity for metabolite chemical-shifts. Based on thorough validation, we established some optimized procedures for rat, mouse and human urine, respectively. By eliminating both pH and dication effects, these methods enable the reduction of intersample chemical-shift variations to 1.5 Hz for all metabolites. The methods will offer ensured data quality for high-throughput, especially robotic urinary metabonomics studies with no need for peak alignments or corrections.

Original languageEnglish
Pages (from-to)4209-4219
Number of pages11
JournalAnalyst
Volume137
Issue number18
DOIs
Publication statusPublished - Sept 21 2012
Externally publishedYes

ASJC Scopus Subject Areas

  • Analytical Chemistry
  • Biochemistry
  • Environmental Chemistry
  • Spectroscopy
  • Electrochemistry

Fingerprint

Dive into the research topics of 'Eliminating the dication-induced intersample chemical-shift variations for NMR-based biofluid metabonomic analysis'. Together they form a unique fingerprint.

Cite this