Abstract
This letter presents a novel implementation of pulse width modulation that improves the quality of the line-to-line output voltages in interleaved multiphase voltage-source inverters (VSIs). In multiphase VSIs with n interleaved parallel-connected legs, the best single-phase output voltage is achieved when the carriers are evenly phase shifted. However, switching among nonadjacent levels can be observed at regular intervals in the line-to-line voltages, causing bad harmonic performance. With the proposed method, switching in the line-to-line voltages happens exclusively between adjacent levels. The modulator utilizes two sets of n evenly phase-shifted carriers that are dynamically allocated. Because of its generality, the proposed implementation is valid for any number of phases and any number of legs in parallel. A MATLAB/Simulink model has been set up for simulation purposes. Selected experimental results obtained from a three-phase VSI made up with two and three legs in parallel per phase are reported, confirming the enhancement attained with the proposed implementation.
Original language | English |
---|---|
Article number | 6860259 |
Pages (from-to) | 1121-1125 |
Number of pages | 5 |
Journal | IEEE Transactions on Power Electronics |
Volume | 30 |
Issue number | 3 |
DOIs | |
Publication status | Published - Mar 1 2015 |
Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2014 IEEE.
ASJC Scopus Subject Areas
- Electrical and Electronic Engineering
Keywords
- Interleaving
- legs connected in parallel
- pulse width modulation
- voltage-source inverter (VSI).