Abstract
The cascaded H-bridge (CHB) low-capacitance static compensator (LC-StatCom) has a limited operating range in the inductive region compared to a conventional StatCom due to the inherent large oscillations on the capacitor voltages. This limitation constitutes a great drawback of CHB LC-StatComs. This article presents an effective hardware-free solution to overcome this drawback. The proposed solution is based on the injection of an optimal third-harmonic circulating current to suitably shape the capacitor voltages aiming at avoiding overmodulation. Considering all the effects of the third-harmonic circulating current, the article proposes a reference design that guarantees a prescribed safe operating voltage limit, thus increasing the operational range of the LC-StatCom. The proposed approach takes into account the inherent induced oscillation on the capacitor voltages. This approach has been verified by simulation and experimentally with a laboratory prototype, corroborating the excellent performance that agrees with the theoretical analysis.
Original language | English |
---|---|
Article number | 9369068 |
Pages (from-to) | 10788-10800 |
Number of pages | 13 |
Journal | IEEE Transactions on Power Electronics |
Volume | 36 |
Issue number | 9 |
DOIs | |
Publication status | Published - Sept 2021 |
Externally published | Yes |
Bibliographical note
Publisher Copyright:© 1986-2012 IEEE.
ASJC Scopus Subject Areas
- Electrical and Electronic Engineering
Keywords
- Arm current
- capacitor voltage ripple
- cascaded H-bridge (CHB)
- circulating current control
- multilevel converter
- static compensator (StatCom)
- zero-sequence current injection