TY - JOUR
T1 - Inhalation performance of pollen-shape carrier in dry powder formulation with different drug mixing ratios
T2 - Comparison with lactose carrier
AU - Hassan, Meer Saiful
AU - Lau, Raymond
PY - 2010/2/15
Y1 - 2010/2/15
N2 - In this study, the drug delivery performance of pollen-shape hydroxyapatite (HA) carriers is assessed and compared with conventional lactose (LA) carriers. Budesonide (Bd) is used as the model drug. Three drug mixing ratios of 2:1, 10:1 and 45:1 (carrier:drug, w/w) are used. The attachment of the drug with the carrier is characterized by sieving test. It is found that the drug content in the blends with HA particles is higher than the blends with LA. In vitro inhalation experiments are also conducted in an Andersen cascade impactor (ACI) equipped with a Rotahaler® at gas flow rates of 30 and 60 L/min. The HA blends show high emitted dose (ED) of 82-90% at 30 L/min while the LA blends are observed to have ED of 69-82% at the same conditions. The high emission of the HA blends also allows high fine particle fraction (FPF) of 10-18% while the FPF of the LA blends are 3-15%. At a gas flow rate of 60 L/min, all the HA and LA blends show compatible ED (83-95% for HA blends and 82-84% for LA blends) and FPF (19-41% for HA blends and 21-34% for LA blends).
AB - In this study, the drug delivery performance of pollen-shape hydroxyapatite (HA) carriers is assessed and compared with conventional lactose (LA) carriers. Budesonide (Bd) is used as the model drug. Three drug mixing ratios of 2:1, 10:1 and 45:1 (carrier:drug, w/w) are used. The attachment of the drug with the carrier is characterized by sieving test. It is found that the drug content in the blends with HA particles is higher than the blends with LA. In vitro inhalation experiments are also conducted in an Andersen cascade impactor (ACI) equipped with a Rotahaler® at gas flow rates of 30 and 60 L/min. The HA blends show high emitted dose (ED) of 82-90% at 30 L/min while the LA blends are observed to have ED of 69-82% at the same conditions. The high emission of the HA blends also allows high fine particle fraction (FPF) of 10-18% while the FPF of the LA blends are 3-15%. At a gas flow rate of 60 L/min, all the HA and LA blends show compatible ED (83-95% for HA blends and 82-84% for LA blends) and FPF (19-41% for HA blends and 21-34% for LA blends).
KW - Drug carrier
KW - Drug mixing ratio
KW - Dry powder inhalation
KW - Emitted dose
KW - Fine particle fraction
KW - Pollen-shape
UR - http://www.scopus.com/inward/record.url?scp=74149085646&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=74149085646&partnerID=8YFLogxK
U2 - 10.1016/j.ijpharm.2009.10.047
DO - 10.1016/j.ijpharm.2009.10.047
M3 - Article
C2 - 19922775
AN - SCOPUS:74149085646
SN - 0378-5173
VL - 386
SP - 6
EP - 14
JO - International Journal of Pharmaceutics
JF - International Journal of Pharmaceutics
IS - 1-2
ER -