Noninvasive investigations of the normal ocular circulation in humans

Leopold Schmetterer*, Susanne Dallinger, Oliver Findl, Karin Strenn, Ursula Graselli, Hans Georg Eichler, Michael Wolzt

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

114 Citations (Scopus)

Abstract

PURPOSE. TO compare the reproducibility of laser interferometric measurements of fundus pulsation, pneumatonometric measurement of pulse amplitude (PA) and pulsatile ocular blood flow (POBF), and Doppler ultrasonic measurements of blood flow velocity in the ophthalmic artery (OA) and the posterior ciliary arteries (PCAs) and to investigate the association of the results obtained with these methods and to characterize ocular hemodynamics during Valsalva maneuver and isometric handgrip. METHODS. All studies were performed in healthy subjects. Fundus pulsation (n = 48), POBF (n = 24), and blood flow velocities (n = 24) were measured at baseline and during the Valsalva maneuver and isometric handgrip. Intraclass correlation coefficients were calculated for test/retest variability, for short-term variability, and for interobserver variability. RESULTS. Intraclass correlation coefficients were between 0.95 and 0.98 for fundus pulsation measurements, between 0.54 and 0.76 for pneumatonometric measurements, between 0.44 and 0.88 for Doppler sonographic measurements in the OA and between 0.32 and 0.60 in the PCAs. There was a high degree of association between pneumatonometric parameters and fundus pulsation amplitude. Valsalva maneuver significantly reduced fundus pulsations, PA, and POBF, whereas isometric handgripping did not change these parameters. CONCLUSIONS. The reproducibility of fundus pulsation measurements was excellent. Reproducibility of pneumatonometric parameters and ultrasonographic measurements in the OA was satisfactory. Reproducibility of ultrasonographic measurements in the PCAs was low. Data obtained during the autonomic stimuli experiments argue against the sole use of systems to measure pulsatile blood flow, if no additional data on flow pulsatility are available. At least in cases when changes in blood pressure are likely to occur the ratio of pulsatile to nonpulsatile blood flow might not be constant and POBF might not be an adequate measure of total ocular blood flow.

Original languageEnglish
Pages (from-to)1210-1220
Number of pages11
JournalInvestigative Ophthalmology and Visual Science
Volume39
Issue number7
Publication statusPublished - Jun 1998
Externally publishedYes

ASJC Scopus Subject Areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Fingerprint

Dive into the research topics of 'Noninvasive investigations of the normal ocular circulation in humans'. Together they form a unique fingerprint.

Cite this