TY - JOUR
T1 - Particle size reduction of poorly water soluble artemisinin via antisolvent precipitation with a syringe pump
AU - Kakran, Mitali
AU - Sahoo, Nanda Gopal
AU - Li, Lin
AU - Judeh, Zaher
PY - 2013/3
Y1 - 2013/3
N2 - The method called antisolvent precipitation with a syringe pump (APSP) was used for reducing the particle size of a poorly water soluble anti-malarial drug, artemisinin (ART) with the aim of improving its dissolution properties. Various process parameters, such as drug concentration, solvent-antisolvent volume ratio, stirring speed, flow rate and temperature were investigated and optimized to produce the smallest particle size. As part of the design of experiment, a percent dissolution surface response model was regressed and statistically assessed to understand the relationship between the process parameters and percent dissolution. The particle size of the commercial ART was reduced from 26.4. μm (diameter) and 30.0. μm (length) to 1.5. μm (diameter) and 3.8. μm (length) by the APSP method, which increased the percent dissolution of ART. The DSC and XRD studies revealed that the crystallinity of ART particles prepared was lower than the commercial ART. The XRD study also revealed the fabrication of two polymorphs of ART, i.e. the orthorhombic and triclinic form. Commercial ART and ART particles fabricated by APSP (in the absence of polymers) were orthorhombic whereas ART prepared in the presence of a polymer, polyvinylpyrrolidone or polyethylene glycol, was of triclinic form.
AB - The method called antisolvent precipitation with a syringe pump (APSP) was used for reducing the particle size of a poorly water soluble anti-malarial drug, artemisinin (ART) with the aim of improving its dissolution properties. Various process parameters, such as drug concentration, solvent-antisolvent volume ratio, stirring speed, flow rate and temperature were investigated and optimized to produce the smallest particle size. As part of the design of experiment, a percent dissolution surface response model was regressed and statistically assessed to understand the relationship between the process parameters and percent dissolution. The particle size of the commercial ART was reduced from 26.4. μm (diameter) and 30.0. μm (length) to 1.5. μm (diameter) and 3.8. μm (length) by the APSP method, which increased the percent dissolution of ART. The DSC and XRD studies revealed that the crystallinity of ART particles prepared was lower than the commercial ART. The XRD study also revealed the fabrication of two polymorphs of ART, i.e. the orthorhombic and triclinic form. Commercial ART and ART particles fabricated by APSP (in the absence of polymers) were orthorhombic whereas ART prepared in the presence of a polymer, polyvinylpyrrolidone or polyethylene glycol, was of triclinic form.
KW - Antisolvent precipitation
KW - Artemisinin
KW - Crystallinity
KW - Dissolution
KW - Particle size
KW - Syringe pump
UR - http://www.scopus.com/inward/record.url?scp=84875268030&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84875268030&partnerID=8YFLogxK
U2 - 10.1016/j.powtec.2012.12.029
DO - 10.1016/j.powtec.2012.12.029
M3 - Article
AN - SCOPUS:84875268030
SN - 0032-5910
VL - 237
SP - 468
EP - 476
JO - Powder Technology
JF - Powder Technology
ER -