Repeatability and reproducibility of total retinal blood flow measurements using bi-directional doppler oct

Stephan Szegedi, Nikolaus Hommer, Martin Kallab, Stefan Puchner, Doreen Schmidl, René M. Werkmeister, Gerhard Garhöfer, Leopold Schmetterer*

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

12 Citations (Scopus)

Abstract

Purpose: To investigate the repeatability and reproducibility of total retinal blood flow measurements using a custom-built dual-beam bidirectional Doppler optical coherence tomography (OCT) system in healthy subjects. Methods: Repeatability and reproducibility were analyzed in 10 and 34 healthy subjects, respectively. For repeatability, measurements were taken twice within 30 minutes, for reproducibility, twice within two to five weeks. Two analysis approaches were compared for calculation of absolute blood velocities: a previously published approach resulting in values for total arterial (QA,abs) and total venous blood flow (QV,abs) and a novel approach taking into account that there is a fixed relation between the phase shift in the two OCT channels (QA,new, QV,new). Repeatability and reproducibility were quantified using intraclass correlation coefficients (ICCs). Results: For QA,abs and QV,abs, ICC values between 0.78 and 0.84 were obtained. QA,new and QV,new values revealed better repeatability and reproducibility as compared to the convential appoach. Repeatability ICCs for QA,new and QV,new were between 0.91 and 0.93, and reproducibility ICCs were between 0.87 and 0.91 indicating excellent reproducibility. Good agreement was observed between total retinal blood flow values as measured from retinal arteries and retinal veins. Conclusions: Measurement of total retinal blood flow using dual-beam Doppler OCT shows excellent reproducibility, which can further be improved by using a novel algorithm for calculating blood velocities in retinal vessels. Translational Relevance: Our data indicate that dual-beam Doppler OCT can be used for longitudinal studies. Hence, quantitative retinal blood flow may be established as a biomarker for progression vascular eye diseases.

Original languageEnglish
Article number34
Pages (from-to)1-9
Number of pages9
JournalTranslational Vision Science and Technology
Volume9
Issue number7
DOIs
Publication statusPublished - 2020
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2020 The Authors.

ASJC Scopus Subject Areas

  • Biomedical Engineering
  • Ophthalmology

Keywords

  • Healthy subjects
  • Repeatability
  • Retinal blood flow

Fingerprint

Dive into the research topics of 'Repeatability and reproducibility of total retinal blood flow measurements using bi-directional doppler oct'. Together they form a unique fingerprint.

Cite this