TY - JOUR
T1 - Reproducibility of retinal vessel oxygen saturation measurements in healthy young subjects
AU - Lasta, Michael
AU - Palkovits, Stefan
AU - Boltz, Agnes
AU - Schmidl, Doreen
AU - Kaya, Semira
AU - Cherecheanu, Alina Popa
AU - Garhöfer, Gerhard
AU - Schmetterer, Leopold
PY - 2012/12
Y1 - 2012/12
N2 - Purpose: An adequate oxygenation and perfusion is essential for the function of the inner retina. Recently, several techniques for the measurement of retinal oxygen saturation became available. We set out to evaluate reproducibility of the measurements using a modified Retinal Vessel Analyzer. Methods: A total of 20 healthy female and male subjects aged between 18 and 35 years (22.9 ± 3.9; mean ± SD) were included. The measurement of retinal oxygen saturation with the retinal oximeter employed in this study is based on optical reflectometry using the different absorption characteristics of oxygenated and deoxygenated haemoglobin. The intraclass correlation coefficients and the coefficients of variation (CV) for test-retest, short-term as well as day-to-day measurements were calculated. Results: The intraclass correlation coefficients were between 0.91 and 0.94 for retinal branch arteries and between 0.84 and 0.88 for retinal branch veins. In retinal arteries, we calculated a test-retest CV of 3.24 ± 3.18% for oxygen saturation measurements. In retinal veins, data were slightly less reproducible with a CV of 4.92 ± 3.57%. Short-term reproducibility of both measurement cycles on each study day was in the same range (CV in retinal arteries: 2.91 ± 2.42% and CV in retinal veins: 4.76 ± 3.14%). The day-to-day coefficient of variation was slightly higher (CV in retinal arteries: 3.97 ± 2.87% and CV in retinal veins: 6.18 ± 3.36%). Conclusion: The reproducibility of haemoglobin oxygen saturation measurements using the retinal oximeter is acceptable. Further studies on the validity of the obtained results are, however, required.
AB - Purpose: An adequate oxygenation and perfusion is essential for the function of the inner retina. Recently, several techniques for the measurement of retinal oxygen saturation became available. We set out to evaluate reproducibility of the measurements using a modified Retinal Vessel Analyzer. Methods: A total of 20 healthy female and male subjects aged between 18 and 35 years (22.9 ± 3.9; mean ± SD) were included. The measurement of retinal oxygen saturation with the retinal oximeter employed in this study is based on optical reflectometry using the different absorption characteristics of oxygenated and deoxygenated haemoglobin. The intraclass correlation coefficients and the coefficients of variation (CV) for test-retest, short-term as well as day-to-day measurements were calculated. Results: The intraclass correlation coefficients were between 0.91 and 0.94 for retinal branch arteries and between 0.84 and 0.88 for retinal branch veins. In retinal arteries, we calculated a test-retest CV of 3.24 ± 3.18% for oxygen saturation measurements. In retinal veins, data were slightly less reproducible with a CV of 4.92 ± 3.57%. Short-term reproducibility of both measurement cycles on each study day was in the same range (CV in retinal arteries: 2.91 ± 2.42% and CV in retinal veins: 4.76 ± 3.14%). The day-to-day coefficient of variation was slightly higher (CV in retinal arteries: 3.97 ± 2.87% and CV in retinal veins: 6.18 ± 3.36%). Conclusion: The reproducibility of haemoglobin oxygen saturation measurements using the retinal oximeter is acceptable. Further studies on the validity of the obtained results are, however, required.
KW - haemoglobin
KW - oxygen saturation
KW - retina
KW - vessels
UR - http://www.scopus.com/inward/record.url?scp=84870491004&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84870491004&partnerID=8YFLogxK
U2 - 10.1111/j.1755-3768.2012.02513.x
DO - 10.1111/j.1755-3768.2012.02513.x
M3 - Article
C2 - 22938808
AN - SCOPUS:84870491004
SN - 1755-375X
VL - 90
SP - e616-e620
JO - Acta Ophthalmologica
JF - Acta Ophthalmologica
IS - 8
ER -